Meta-analysis of sonicate fluid in blood culture bottles for diagnosing periprosthetic joint infection

Cheng Li, Nora Renz, Cristina Ojeda Thies, and Andrej Trampuz

Keywords: Arthroplasty, Periprosthetic joint infection, Diagnose, Blood culture bottles, Sonicate, Meta-analysis

Abstract. Introduction: Periprosthetic joint infection (PJI) is the most serious complication after arthroplasty, and the diagnosis of PJI is still challenging with modern medical technology. To improve the diagnostic rate, combined diagnostic methods are gradually beginning to be used to diagnose PJI. Sonication is one accurate way to diagnose PJI, but there is minimal research regarding the diagnostic value of sonicate fluid (SF) in blood culture bottles (BCB). Therefore, we evaluated this combined diagnostic method by meta-analysis.

Methods: We searched English publications in electronic databases regarding the use of sonicate fluid in blood culture bottles (SF-BCB) for diagnosing PJI, screened the literature according to inclusion criteria, assessed the quality of the selected literature, and collected information regarding SF-BCB.

Results: This meta-analysis includes 4 studies that evaluated SF-BCB for the diagnosis of PJI. The pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnostic odds ratio (DOR) are 0.85 (95% Confidence interval [CI], 0.77 to 0.91), 0.86 (CI, 0.81 to 0.91), 5.34 (CI, 3.13 to 9.11), 0.16 (CI, 0.06 to 0.48) and 39.01 (CI, 9.04 to 168.35), respectively. The area under the curve (AUC) of the summary receiver operating characteristic (SROC) is 0.9186 (standard error, 0.0205).

Conclusion: SF-BCB has great value for the microbiological diagnosis of PJ, especially for patients with prior antibiotic treatment.